Toyota Supra, Yaris GR, Tuning & Performance
| | | lee@srdtuning.com | 01444 457026

Link MX5Link – MX5X

Link MX5Link – MX5X

£1,140.00

Easy to install. Affordable. Reliable.  
G4X PlugIn ECUs offer the latest in engine management technology, designed to easily maximize the potential from your car.
This ECU fits inside the factory OEM enclosure. Installation is a breeze, with no alteration of the factory wiring loom required for the models listed below.

Designed for the MX5 B6ZE(RS) / BP 1.8L engine.

  • Please check your connector matches the header in the listed photo before purchasing.
  • This ECU works for manual transmissions only.
  • Includes onboard 4 bar or 7 bar MAP sensor
  • Knock control not available on this ECU.
  • Most factory features are supported
  • Check the features tab for I/O expansion options

Suitable applications:  

1600 1989-1997 NA MX5

1800 1989-1997 NA MX5

1800 323 GTX

1800 323 GTR

Please note: This ECU does not fit NB, NC, ND models. This unit is only suitable for the 2 plug ECU and not the later 3 plug models). 

In stock

Description

G4X PlugIn Key Features (where applicable):
Up to 6D fuel and ignition mapping
Precision closed loop cam control (four cam, independent control)
Sequential fuel delivery
Digital triggering, all OEM patterns
OEM idle hardware supported
5D boost control with three switchable tables
Motorsport features – antilag, launch, flat shift
Continuous barometric correction (on board)
CAN port
QuickTune – automated fuel tuning
Individual cylinder correction
USB tuning cable included
Stats recording into on-board memory
Gear compensations for spark, boost and fuel
Real time selectable dual fuel, ignition and boost maps
Sync and crank sensors can be a combination of Hall effect, variable reluctance or optical
Boost control referenced to gear, speed or throttle position
512 mega bytes data logging memory
Staged injection
Knock with “windowing”

I/O Expansion Options:
The following expansion connector inputs/outputs are provided:
Expansion Connector 1
SGnd                Sensor Ground Only
+5V                Low Current +5V Supply
DI 7                Digital Input
DI 6                Digital Input
Volt 5                Analog 0-5V input
Volt 6                Analog 0-5V input
Temp4                Temperature sensor input
Temp3                Temperature sensor input

Expansion connector 2
SGnd                Sensor Ground Only
+5V                Low Current +5V Supply
Ign 7                Auxiliary Output
Ign 8                Auxiliary Output
DI 8                Digital Input
DI 9                Digital Input
Volt 9                Analog 0-5V input
Volt 10                Analog 0-5V input

Download Manual